Operating Instructions Safety System CES-AP-C.2-AH
21
Switching distances
Operating distance for center offset m = 0
(only in combination with actuator CES-A-BLN-...)
Parameter Value Unit
min. typ. max.
Switch-on distance - 15 -
mm
Assured switch-on distance s
ao 
1)
10 - -
Switching hysteresis 
1)
1 2 -
Assured switch-off distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
Typical operating distance
(only in combination with actuator CES-A-BLN-...)
Fig. 6: Typical operating distance
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm 
must be maintained so that the operating distance of the side lobes is not entered.