Figure 5: Connection example for series connection with reset and changeover
switch.
Y-distributor
Terminating plug
1
3
5
2
4
1 6 2 78 5 3 4
5
2
4
1
3
RST
0V
IA
OUT
OB
OA
UB
IB
UB
OA
0V
OB
RST
UB
IA
0V
IB
RST
2
4
1UB
IA
IB
Safety Outputs
Read Head
Read Head
Safety Outputs
SafetyInputsSafety Inputs
Y-distributor
Y-distributor Y-distributor
Terminating plug
Eval Unit
Read Head
Safety Outputs
Safety Inputs
5
OUT
4
OB
2
UB
8
RST
6
IA
1
IB
7
0V
5
OUT
3
OA
4
OB
2
UB
8
RST
6
IA
1
IB
7
0V
0V
3
OA
4
OB
-S1
12
11 14
2
UB
8
RST
6
IA
1
IB
7
0V
5
OUT
3
OA
24
V
CES CESCES