Euchner CES-AR-CL2-CH (Multicode) Manual de usuario Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
Operating Instructions Safety Switches CES-AR-C.2-CH
16
Warning!
In case of an error, loss of the safety function through incorrect connection.
Ì To ensure safety, both safety outputs (OA and OB) must always be evaluated. 
Single-channel use of the safety outputs leads to a loss of the category in 
accordance with EN ISO 13849-1.
CES-AR-C #1
IB1
UB2
OA3
OB4
Plug connector (8-pin)
OUT5
IA6
0V7
RST8
WH
BN
GN
YE
GY
PK
BU
RD
GND
DC 24 V
-K1
-K2
-M1 -M2
M M
A1
A2
A1
A2
13
14
13
14
Fig. 4: Example of incorrect connection.