More than safety.System ManualNon-contact Safety SystemCES-A-W5H-01 (Multicode)
System Manual Safety System CES-A-W5H-0110Actuator and safety switch must be fitted so thatthe front faces are at the minimum switch-on distance 0.8 x
System Manual Safety System CES-A-W5H-0111Electrical ConnectionWarning!Loss of the safety function due to incorrect connection. Not suitable for safet
System Manual Safety System CES-A-W5H-0112Caution!Power devices which are a powerful source of interference must be installed in a separate location a
System Manual Safety System CES-A-W5H-0113Safety switch CES-A-W5...Voltage drop as a function of switching current and cable length (examples)Switchin
System Manual Safety System CES-A-W5H-0114Correct connectionImportant!To ensure safety, both safety outputs (LA and LB) must be evaluated.To achieve c
System Manual Safety System CES-A-W5H-0115Connection exampleCES-A-W5H-01Important!To achieve category 4 according to EN ISO 13849-1, it is necessary t
System Manual Safety System CES-A-W5H-011683574216Pin assignment safety switch CES-A-W5...LED indicatorsSTATE LED green Normal operation Flashing
System Manual Safety System CES-A-W5H-0117Functional checkAfter installation and any fault, the safety function must be fully checked. Proceed as foll
System Manual Safety System CES-A-W5H-0118System Status TableOperating modeActuator/Guard positionSafety outputs LA and LBPLCLED displayStateOutputOUT
System Manual Safety System CES-A-W5H-0119Technical DataNoteIf a product data sheet is included with the product, the information on the data sheet ap
System Manual Safety System CES-A-W5H-012ContentsCorrect Use 3Possible combinations for CES components 4Exclusion of Liability and Warranty 4General
System Manual Safety System CES-A-W5H-0120Technical DataParameterValueUnitmin. typ. max.Housing material Plastic PBT V0 GF30Dimensions According to EN
System Manual Safety System CES-A-W5H-0121Actuator CES-A-BPACube-shaped design 40 x 40 mmDimension drawing CES-A-BPATechnical DataParameterValueUnitmi
System Manual Safety System CES-A-W5H-0122Typical operating distanceOnly in conjunction with actuator CES-A-BPA on surface mounting.Operating distance
System Manual Safety System CES-A-W5H-0123Actuator CES-A-BBA/CES-A-BCACube-shaped design 42 x 25 mmCES-A-BCA suitable for use in aggressive media (e.g
System Manual Safety System CES-A-W5H-0124Typical operating distanceOnly in combination with actuator CES-A-BBA or CES-A-BCAOperating distance for cen
System Manual Safety System CES-A-W5H-0125Inspection and ServiceWarning!Loss of the safety function because of damage to the device.In case of damage,
System Manual Safety System CES-A-W5H-0126Declaration of Conformity
System Manual Safety System CES-A-W5H-0127
More than safety.Euchner GmbH + Co. KGKohlhammerstraße 16D-70771 [email protected]:097526-07-01/12Title: Syste
System Manual Safety System CES-A-W5H-013Correct UseThe Coded Electronic Safety switches series CES are safety devices for monitor-ing movable safety
System Manual Safety System CES-A-W5H-014Possible combinations for CES componentsSafety switchActuatorCES-A-BBA071840CES-A-BCA088786CES-A-BDA084720CES
System Manual Safety System CES-A-W5H-015General Safety InstructionsCheck the safe function of the safety guard particularlyafter any setup workafter
System Manual Safety System CES-A-W5H-016System DescriptionAs the unique actuator codes are not evaluated, the CES-A-W5... version can only be used fo
System Manual Safety System CES-A-W5H-017Block diagram123456780V+ ULALBOUT+LA-LAB+LBBI1O1 0 V0 VE2I9O90 V0 V0 VOUTDC +24 V+LB-LABLB+LALA+ U0V(RD)(BU)(
System Manual Safety System CES-A-W5H-018Changing the approach directionCaution!Risk of damage to equipment as a result of trapped cables.Make sure th
System Manual Safety System CES-A-W5H-019InstallationCaution!Safety switches must not be bypassed (bridging of contacts), turned away, remov