System Manual Safety System CES-A-W5H-01
19
Technical Data
Note
If a product data sheet is included with the product, the information on the data
sheet applies in case of discrepancies with the operating instructions.
Safety switch CES-A-W5...
Read head and evaluation unit integrated in the standard housing
Semiconductor output
M12 plug connector
Dimension drawing
Switching characteristics
2 safety outputs
(semiconductor outputs)
1 door monitoring output
(semiconductor output,
not a safety output)
Typical operating distance
See page 22 and page 24.
ApprovalsApprovals
+LA
LA
+LB
LB
+UB OUT
+LA
LA
+LB
LB
+UB
OU T
Safety guard
closed (actuator detected) open (actuator not in the operat-
ing distance)
Read
head
Actuator
Read
head
30
M12x1
±0,1
±0,1
13
118
45,5
40
5,3
60
7,3
( 131 )
16,5
40,5
30
40
LED gn
LED rd/ye
Active face