Euchner CES-I-AR-M-C04 (Multicode) Manual de usuario Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
Operating Instructions Safety Switch CES-I-AR-M-C04
27
Operating distances
Operating distance for center offset m = 0
(only in combination with actuator CES-A-BBN-C04 from approach direction A or B)
Parameter Value Unit
min. typ. max.
Switch-on distance - 15 -
mm
Assured switch-on distance s
ao
1)
10 - -
Switching hysteresis
1)
1 2 -
Assured switch-off distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
1) On approach in Z direction
Operating distance for center offset m = 0
(only in combination with actuator CES-A-BBN-C04 from approach direction C or D)
Parameter Value Unit
min. typ. max.
Switch-on distance - 11 -
mm
Assured switch-on distance s
ao
1)
6 - -
Switching hysteresis
1)
1 2 -
Assured switch-off distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
1) On approach in x direction
Typical operating distance in approach direction A
(Only in combination with actuator CES-A-BBN-C04)
Figure 7: Typical operating distance
Approach direction
A B
Approach direction
C D
-25
-30
X
10
5
15
20
-20
-25
-30
-40
-35
-15
-10
-5
-10
20
25
30
15
10
40
35
5
Y
-5
-15
-20
Z
10
15
20
25
5
30
For a side approach direction (y direction) for the actuator and safety switch,
a minimum distance of s = 6 mm must be maintained so that the operating distance
of the side lobes is not entered.
Vista de pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 33 34

Comentarios a estos manuales

Sin comentarios