8.4.1 Write process
When this command is used, the Electronic-Key must be in the Electronic-Key adapter, and must be
removed from within the operating distance only after the reply message has been received.
Command message (message core, PC→ EKS, see Figure 2):
TP (device addr.) (start addr. user data) (number of bytes of user data) (user data)
Reply message (message core, EKS → PC, see Figure 3):
RF (device addr.) (00
hex
, 00
hex
) (status number)
Byte no. Description
Command identification
Start address for the user data
Number of bytes of user data
ASCII or hexadecimal or BCD (code transparent)
Figure 2: Command message write to read/write Electronic-Key (message core)
Byte no. Description
Command identification
Padding data
Figure 3: Reply message write to read/write Electronic-Key - status (message core)
* Status number 00
hex
: No error
02
hex
: Electronic-Key not in the operating distance
(For further status numbers see section 8.6)