Operating Instructions Safety Switch CES-AP-C01-CH
14
Warning!
In the event of a fault: Loss of the safety function due to incorrect connection.
Ì To ensure safety, both safety outputs (OA and OB) must always be evaluated.
Single-channel use of the safety outputs leads to a loss of the category in
accordance with EN ISO 13849-1.
GND
DC 24 V
CES-AP-C
n.c.1
UB2
OA3
OB4
M12 plug-connector
(8-pin)
DIA5
n.c.6
0V7
RST8
-K1
-K2
-M1 -M2
M M
A1
A2
A1
A2
13
14
13
14
Figure 3: Example of incorrect connection
Connecting CES-AP-...-SB-... (pin 5 not assigned) to
a decentralized peripheral system (e.g. ET200pro
series from Siemens)
Observe the information in the section Particularities for operation on decentralized
peripheral systems on page 11 before connecting the device.
Figure 4: Connection example for connection to decentralized peripheral sys-
tems
CES-AP-...-SB-...
UB1
FO1A2
0V3
FO1B4
S1: M12 plug-connector
(5-pin)
n.c.5
decentralized
periphery
e.g. ET 200pro
PLC
DI
1
5
2
4
3
1
5
2
4
3
DO