Euchner CES-AP-C01-CH (Multicode) Manual de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
Operating Instructions Safety Switch CES-AP-C01-CH
22
Switching distances
Operating distance for center offset m = 0
(only in conjunction with actuator CES-A-BPA on surface mounting)
Parameter Value Unit
min. typ. max.
Switch-on distance - 22
1)
-
mm
Assured switch-on distance s
ao
18 - -
Switching hysteresis 1 2 -
Assured switch-off distance s
ar
- - 58
1) On surface mounting on aluminum; in a non-metallic environment the typical switching distance increases to 30 mm.
Typical operating distance
(only in conjunction with actuator CES-A-BPA on surface mounting)
45
40
35
30
25
20
15
10
-45
5
Z
Y
X
5
10
15
20
25
30
35
40
45
45
40
-45
35
30
25
20
15
10
5
For a side approach direction for the actuator and read head, a minimum distance of s = 6 mm
must be maintained so that the operating distance of the side lobes is not entered.
Figure 6: Typical operating distance