AS-i 3.0 Command Interface Commands of the Command Interface
Subject to reasonable modifications due to technical advances Id.-No.: 102875 Issue date - 3.12.2007 EUCHNER GmbH + Co. KG
Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen Tel. +49/711/7597-0, Fax +49/711/753316
20
n is the length of the sub-string that is to be written to the buffer starting from index
(i). When i = 0, the transfer is started.
Request
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
14E
16
2T circuit
3 slave address
4 buffer index (i) high
5 buffer index (i) low
6
command
1
1. For a list of all supported commands <see table "Espoused commands", page
20>.
7 number of (n)
8 data 0
… ...
n+7 data n-1
Espoused commands
see page Command Description
page 23
1
read string S-7.4 ID
page 23
2
read string S-7.4 diag
page 23
3
read string S-7.4 param string
page 23
4
write S-7.4 param string
page 24
5 transfer S-7.5
page 24
6
read S-7.5 cyclic 16-bit slave configuration
page 24
7
read safety monitor sorted by OSSD
page 26
8
read safety monitor unsorted (all devices) by OSSD
page 26
9
reserved / not defined
!!! page 27
10
safety monitor diagnosis
!!! page 27
11
shutdown-history, separate for each release circuit
!!! page 27
12
safety monitor diagnosis, but the module allocation has been con-
sidered
!!! page 27
13
safety monitor diagnosis, but the module allocation has been con-
sidered
!!! page 28
14
diagnosis / shutdown-history, separate for each release circuit
!!! page 30
15
safety status
!!!
The commands 10 ... 15 are available only with safety monitors (external and
integrated) in the version 2 and higher.