AS-i 3.0 Command Interface Commands of the Command Interface
Subject to reasonable modifications due to technical advances Id.-No.: 102875 Issue date - 3.12.2007 EUCHNER GmbH + Co. KG
Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen Tel. +49/711/7597-0, Fax +49/711/753316
67
4.7.4 Enhanced diagnosis
Since the "Safety at Work“ monitor diagnosis is longer than the maximum size of
the command interface, it must be read with several adjacent requests.
The byte 5 (‘index’) declares the start index in the array of diagnostic data. If this
start index is 0, the whole diagnosis is fetched from the monitor and stored to an
internal buffer. Otherwise, the AS-i Master will respond out of the internal buffer.
Thus, even though several requests are necessary to read the whole buffer, data
integrity is maintained.
The diagnosis array is set up as follows:
Request
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
17E
16
2T
L
1
1. L=1 long diagnosis for advanced monitor
U
2
2. U=1 unsorted diagnosis (all devices)
circuit
302
16
4 slave address
5 index
Response
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
17E
16
2T result
3 diagnosis byte #index+0
4 diagnosis byte #index+1
……
n diagnosis byte #index+n-3
Safety Monitor Diagnosis Array
"basic function range" and "sorted by OSSD"
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
000
16
1 state of monitor
2 state of OSSD 1
3 state of OSSD 2
4 number of devices not green, OSSD1
5 number of devices not green, OSSD2
6 device index 32, OSSD 1
7 color of device 32, OSSD 1
8 device index 33, OSSD 1
9 color of device 33, OSSD 1