Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B
26
Technical Data
Parameter Value Unit
min. typ. max.
Housing material Fortron, reinforced thermoplastic, fully encapsulated
Dimensions 42 x 25 x 12 mm
Weight (incl. 10 m cable) 0.3 kg
Ambient temperature -25 - +70 °C
Degree of protection IP67/IP69K
Installation position Any
Method of operation Inductive
Power supply Via evaluation unit
In combination with actuator CES-A-BBA on evaluation unit CES-A-UEA...
Assured switch-off distance S
ar
--32
mm
Operating distance for center offset m = 0
1)
- Switch-on distance - 15 -
- Assured switch-on distance S
ao
10 - -
- Switching hysteresis 0.5 2 -
Minimum distance s with lateral approach direction - 3 -
In combination with actuator CES-A-BDA on evaluation unit CES-A-UEA...
Assured switch-off distance S
ar
--33
mm
Operating distance for center offset m = 0
2)
- Switch-on distance - 16 -
- Assured switch-on distance S
ao
11 - -
- Switching hysteresis 0.5 2 -
Minimum distance s with lateral approach direction - 4 -
Connection cable Hard-wired encapsulated connection cable, with crimped ferrules
PVC, ∅ 4.6 mm
PUR, ∅ 4.8 mm, suitable for drag chain
Cable length - - 25 m
1) These values apply to non-flush installation of the read head and actuator.
2) These values apply to metal-free surrounding material. Other materials on request.
Ordering table
Series Cable/connection type Cable length "l" [m] Order no. / item
CES-A-LNA...
V
Cable PVC
5
071845
CES-A-LNA-05V
10
071846
CES-A-LNA-10V
15
071847
CES-A-LNA-15V
25
071975
CES-A-LNA-25V
P
Cable PUR
5
077806
CES-A-LNA-05P
10
077807
CES-A-LNA-10P
15
084682
CES-A-LNA-15P
Comentarios a estos manuales