Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B
28
Pin assignment
Read head with plug connector
Technical Data
Parameter Value Unit
min. typ. max.
Housing material Fortron, reinforced thermoplastic, fully encapsulated
Dimensions 42 x 25 x 12 mm
Weight (incl. 10 m cable) 0.3 kg
Ambient temperature -25 - +70 °C
Degree of protection IP67/IP69K
Installation position Any
Method of operation Inductive
Power supply Via evaluation unit
In combination with actuator CES-A-BBA on evaluation unit CES-A-UEA...
Assured switch-off distance S
ar
--32
mm
Operating distance for center offset m = 0
1)
- Switch-on distance - 15 -
- Assured switch-on distance S
ao
10 - -
- Switching hysteresis 0.5 2 -
Minimum distance s with lateral approach direction - 3 -
In combination with actuator CES-A-BDA on evaluation unit CES-A-UEA...
Assured switch-off distance S
ar
--33
mm
Operating distance for center offset m = 0
2)
- Switch-on distance - 16 -
- Assured switch-on distance S
ao
11 - -
- Switching hysteresis 0.5 2 -
Minimum distance s with lateral approach direction - 4 -
Connection M8 plug connector (snap-action and screw terminals), 3-pin
Connection cable - - 25 m
1) These values apply to non-flush installation of the read head and actuator.
2) These values apply to metal-free surrounding material. Other materials on request.
Ordering table
Series Order no. / item
CES-A-LNA-SC
077715
CES-A-LNA-SC
H11 H12 SH1
1
3
4
BN
WH
Screen
View on the plug
connector of the
read head
Evaluation unit
CES-A-UEA...