Euchner CES-A-UEA-04B (Multicode) Manual de usuario Pagina 38

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 37
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B
38
Actuator CES-A-BMB
Ì Cylindrical design M12 x 75
Ì In combination with evaluation units CES-A-UEA..., read head CES-A-LMN-SC
(operating distance on request for read head CES-A-LNA.../LCA...)
Dimension drawing
Notes
Ì The actuator can be screwed into the M12 x 0.75 thread provided with the aid
of an insertion tool (Order No. 037 662).
Ì Flush installation of the actuator in steel is allowed.
Technical Data
Parameter
Value
Unit
min. typ. max.
Housing material Stainless steel
Dimensions M12 x 0.75, depth 6 mm
Weight 0.002 kg
Ambient temperature -25 - +70 °C
Degree of protection IP67
Installation position Active face opposite read head
Power supply Inductive via read head
Ordering table
Series Version/Comment Order no. / item
CES-A-BMB
-
077791
CES-A-BMB
Insertion tool
For actuator CES-A-BMB
037662
11
0,80
6
M12x0,75
Active face
Vista de pagina 37