Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B
33
Read head CES-A-LMN-SC
Ì Cylindrical design M12
Ì M8 plug connector (snap-action and screw terminals)
Dimension drawing
Note
The read head is allowed to be installed as a maximum up to the clear zone (area
of the active face without metal housing).
Typical operating distance
With evaluation unit CES-A-UEA... and actuator CES-A-BMB
Note
A minimum distance of s = 1.2 mm must be maintained.
Approvals
17
5
32
19,7
s
m
35
4
8
30
M12x1
M8x1
37
1)
1)
Reading distance
Centre offset
connected
Active face
1) Clear zone (area of the active face without metal housing)
-4-6 -2 0
Centre offset m [mm]
Distance s [mm]
OFF
ON
Switch-on
distance
ON
OFF
Hysteresis
Distance sS
ao
Output state
Switch-off
distance
OFF
-8 2 864
2
4
6
8
Actuator
Read
head
s
m
not permissible area not permissible area
Hysteresis
Vista de pagina 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 43 44

Comentarios a estos manuales

Sin comentarios